![]() 'CCFL Wide Gamut' will match 'LCD CCFL Wide Gamut PVA' and 'LCD CCFL Wide Gamut IPS'). instrument (required if type=ccmx) Instrument name, e.g. ![]() ![]() Will do a semi-fuzzy match even if not using * (e.g. 'i1 Display' will match 'Gretagmacbeth i1 Display', but not 'Gretagmacbeth i1 DisplayPro, ColorMunki Display'). Reference (optional) Reference instrument name, e.g. xml=1 (optional) Return result as XML instead of plain text. json=1 (optional) Return result as JSON instead of plain text. html=1 (optional) Return result as HTML with links to the actual CGATS data. On success, will return HTTP status 200 OK, with the response body containing the payload in form of the matching database entry/entries. An error message will be returned on failure with HTTP status 400 if there is a missing/invalid parameter, or 500 Internal Server Error on database and other critical internal errors. Multiple entries may be returned if not using the hash parameter. Note: Instrument names in CCMX/CCSS files will (and should) contain vendor prefixes. View a specific correction, identified by hash View CCMX for a specific display device & instrument combination ?get=1&type=ccss&display=*&technology=LCD &json=1 &xml=1 &html=1 View CCSS for a specific display technology ?get=1&type=*&manufacturer=NEC&display=*&instrument=* &json=1 &xml=1 &html=1 View all entries for a specific manufacturer These can be omitted for queries and will automatically be stripped for brevity in entries outside of actual CCMX/CCSS data. Parameters: cgats (required) The CCMX/CCSS file contents, application/x-manufacturer_id (required if MANUFACTURER_ID not present in CGATS data) Three-letter display device manufacturer PnP ID. CCMX/CCSS files normally don't include a MANUFACTURER_ID string, but it is recommended to add it either manually or with this parameter (see note and examples below). manufacturer (required if MANUFACTURER not present in CGATS data) Display device manufacturer. CCMX/CCSS files normally don't include a MANUFACTURER string, but it is recommended to add it either manually or with this parameter (see note and examples below). reference (optional, only applicable for CCSS) Reference instrument name (i.e. the spectrometer that was used to create the CCSS file, not the colorimeter), e.g. CCSS files normally don't include a REFERENCE string, but it is recommended to add it either manually or with this parameter (see note and examples below).
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |